Danh mục sản phẩm
TIN TỨC
|
Aspirating Somke Detector
ASD-TC5802 Suction-type Smoke
-
▪ High precise pipeline sampling and high sensitivity
▪ Operating environment: clean, large places, or places with high-temperature, high-humidity or strong electromagnetic radiation
▪ Application places: warehouses, offices, production sites, airports, factories, historical buildings, clean rooms, EDP rooms, communication exchange rooms, shops, cinemas, leisure centers, churches, libraries, hotels, hospitals, electric and nuclear power plants, storerooms, subways and etc
▪ Wall-mounted structure
Technical Specifications
|
|
ASD-TC5801
|
ASD-TC5802
|
|
Operating voltage
|
Bus voltage:24V, range : 16V~28V Power: DC24V, range :DC20V~DC28V
|
|
Operating current
|
Bus:standby current≤1 mA, alarm current≤1 mA
Power Supply:standby current≤0.9 A,
|
Bus:standby current≤1 mA,
alarm current≤1 mA
Power Supply:standby current≤1.8A,
|
|
Relay output
|
1A/24VDC, 1A/120VAC
|
|
Networking mode
|
Loop communication, RS-485, CAN bus loop communication
|
|
Information storage capacity
|
Fire log: 1000 items, fault log: 1000 items and disable log: 1000 items
|
|
Max sampling length of single pipe
|
100m
|
|
Number of sampling loop2
|
4
|
|
Material of enclosure
|
Metal
|
|
Ingress protection rating
|
IP30
|
|
Dimensions (L×W×H)
|
290mm×125mm×350mm
|
476mm×125mm×350mm
|
|
Operating environment
|
Temperature:-10℃~+55℃Relative humidity:10%~95%, non-condensing
|
ASD-TC5801 Suction-type Smoke
▪ High precise pipeline sampling and high sensitivity
▪ Operating environment: clean, large places, or places with high-temperature, high-humidity or strong electromagnetic radiation
▪ Application places: warehouses, offices, production sites, airports, factories, historical buildings, clean rooms, EDP rooms, communication exchange rooms, shops, cinemas, leisure centers, churches, libraries, hotels, hospitals, electric and nuclear power plants, storerooms, subways and etc
▪ Wall-mounted structure
Technical Specifications
|
|
ASD-TC5801
|
ASD-TC5802
|
|
Operating voltage
|
Bus voltage:24V, range : 16V~28V Power: DC24V, range :DC20V~DC28V
|
|
Operating current
|
Bus:standby current≤1 mA, alarm current≤1 mA
Power Supply:standby current≤0.9 A,
|
Bus:standby current≤1 mA,
alarm current≤1 mA
Power Supply:standby current≤1.8A,
|
|
Relay output
|
1A/24VDC, 1A/120VAC
|
|
Networking mode
|
Loop communication, RS-485, CAN bus loop communication
|
|
Information storage capacity
|
Fire log: 1000 items, fault log: 1000 items and disable log: 1000 items
|
|
Max sampling length of single pipe
|
100m
|
|
Number of sampling loop2
|
4
|
|
Material of enclosure
|
Metal
|
|
Ingress protection rating
|
IP30
|
|
Dimensions (L×W×H)
|
290mm×125mm×350mm
|
476mm×125mm×350mm
|
|
Operating environment
|
Temperature:-10℃~+55℃Relative humidity:10%~95%, non-condensing
|
|